Annual fire extinguisher inspection

Annual fire extinguisher inspection
Annual fire extinguisher inspection


How is annual fire extinguisher inspection? Each of places required to have their own fire extinguisher as one investment past the occurrence of unwanted things such as fire. But further things after that compulsion to get regular grant upon existing flare extinguishers. Fire Extinguishers infatuation general checkup with annual fire extinguisher inspection. So, the flare extinguishers not experiencing an mistake due to broken or other things.

As for the extinguishers which have used, it needs to recharge again the extinguisher agent. So, it can work again taking into account the maximum give leave to enter taking into account needed again. Replenishment needs to be over and done with within a time of 2-5 years or considering tubes have been used.

Monthly and annual fire extinguisher inspection


To get the best be active of flare extinguishers, after that he had to attain some checking ember extinguishers at regular intervals behind monthly and annual blaze extinguisher inspection. Routine money carried out each month. There is label check that archives when the last extinguishers have the inspection. As for inspection such as checking the overall firefighting equipment ranging from the smallest situation to the checking of the contents and gas pressure.

Monthly flame extinguisher inspection

1. Checking taking into consideration the sight of the needle position, after that unfilled positions located upon gas or in the green zone in the control area
2. create distinct that the seal is not damaged or floating in the cartridge tube
3. make certain the funnel has no stains or dirt that interfere behind the area
4. Always put the tube in a safe and easily accessible in view of that that the tubes always clean, avoid corrosion, dust and generally closes the area pressure control

5. For sober chemical fire extinguisher, torment yourself to reverse point of view of the tube periodically. So, the powder does not deaden and reward tube once again to its native position
6. create distinct that the flare hanged user-friendly tube remains in the aim of a stable and strong.
7. Avoid putting flame Extinguishers in the area who dealing directly later the sunlight, or exposed to rain
8. We suggest that you put the flame extinguishers that have a cap or bin if in outdoors.

Annual fire extinguisher inspection


Here is an annual flame extinguisher inspection each year. In the inspection of flame extinguisher to know the let in of each tool still feasible to use.

1. For tubes subsequent to powder, check the powder has out cold or moist. Then, fill the annual blaze extinguisher inspection tags
2. create definite that the tube kept clean from dirt, keep the sticker the directions nevertheless readable. Then, the equipment such as hoses and funnels not dirty and clogged, clamp the hose and the valve not damaged
3. make definite that the indicator play properly
4. make positive the needle to prick the cartridge in a tidy and sharp. Then, always complete this lubricant upon needles in order not to experience a jammed or broken
5. Note the areas of pipes for gas and agent channels always clean.

6. Check the Pen spring and Valve undamaged as bent or broken
7. Check every the rubber seals or o-rings, don't forget to apply lubricant consequently that the rubber not experiencing a brittle
8. Preferably performed refilling extinguisher if the carbon dioxide fire extinguisher experiencing a tapering off of 10% of the sum weight
9. Always check the thread and always apply a lubricant to the screw.
10. consider the safety pin back in and seal, and later reach the recording and manage to pay for alerts on any psychotherapy or treatment